	Loadcalc Plus Start Up Manual - Revision 10/05/96
	Windows 3.1 or 95 Required & VBRUN300.DLL (Included)

	Welcome to LoadCalc Plus.....
    
	Registered & Unregistered Users Should Read This....
   
	Unregistered Shareware Versions of LoadCalc Plus
	are provided for EVALUATION ONLY, they cannot be
	used in any Business pursuit or other activity for
	monetary gain. The unregistered version it limited
	to 10 activations after which it is disabled.
    
	Continued use of LoadCalc Plus requires that the
	user register with and pay the appropriate fees to
	ATEC (All-Temp Energy Consultants) 620 Harding Street,
	Waupaca, WI. 54981, (715) 258-0986.
    
	Upon receipt of the $89.95 registration fee, ATEC will
	provide the registered user with a registration number
	that once entered will reactivate disabled evaluation  
	versions (V.1096 & above) of LoadCalc Plus and disable
	evaluation screens and run limiting.

	Product support, notification of updates and updates
	for for the reduced cost of $39.95 is only available
	to registered users.
    
	Other HVAC/R software in the marketplace normally
	sells for $250.00 to $395.00 per module. Loadcalc Plus
	with its graphical interface, on line help, and many other
	features make it an exceptional bargin for its modest
	price, especially so, since it's a Shareware Product, you
	won't see anyone else offering their fully functional
	HVAC/R software modules as Shareware or for $89.95.
    
	The authors enthusiasm to continue this offering on
	a Shareware basis will be based on the honesty of end
	users to register with ATEC.
    
	As with any software of this type, it will continue
	to undergo improvements to improve ease of use, remove
	bugs (hope there ain't any) and expand its capabilities.
   
	To register, send a money order or cashiers check
	for $89.95 to:
   
	ATEC 620 Harding Street Waupaca, WI.  54981
   
	REMEMBER to include:
    
	Your Full Name
	Complete Address
	Telephone Number
	Business Name (If Applicable)
	Date You Downloaded LoadCalc Plus (Required For Reg#)
	

	BEFORE WE START

	If LoadCalc Plus doesn't meet your needs, remember that
	you had the opportunity to try it before you spent your
	hard earned money on it, also keep in mind that its
	purpose and design was intended to provide the small to
	medium size HVAC/R contractor with a tool to aid them
	in properly sizing HVAC/R equipment for residential and
	light to medium size commercial applications, further,
	if you elect to register and pay the $89.95 for LoadCalc
	Plus, you've just saved yourself hundereds of dollars.
	The low cost for LoadCalc Plus also makes it affordable
	for the smaller contractor with tighter budget constraints
	who isn't in a position to pay 	$250.00 to $1,500.00 for
	an HVAC/R design software package.
	
	INSTALLATION

        1. Make a directory titled LJ.

        2. Copy the self-extracting file on the diskette to this
	directory.

	3. Type the name of the file and hit return.

	4. Copy the file named VBRUN300.DLL to your \WINDOWS\SYSTEM
	DIRECTORY.

	5. Configure your windows menu bar settings to run
	the program from this directory. A "LJ" icon is included
	with the program files.

	4. The program windows (screens) are all maximized
	on start-up, as with any windows software, you may
	drag and reduce their size with your mouse to suit
	your individual perference.

	OVERVIEW

	1. LOADCALC PLUS is a heating and air-conditioning
	load calculation tool with logic based on mathematical
	and industry standards as they apply to calculation of
	BTUH loads for HVAC systems.

	2. LOADCALC PLUS heating and air-conditiong modules
	come equipped to handle up to 10 zones, you can
	calculate an entire structure as one zone or break it
	down in as many as 10 zones. LOADCALC PLUS features
	a complete file server which allows the user to LOAD,
   	SAVE and DELETE files as well as switching drives and
	directories.

	3. LOADCALC PLUS is equipped with a file printing
	feature that allows the user to select and print a
	single zone or mutiple zones of choice. The user can easily
	toggle between zones for editing and review. The print
	feature prints the zone forms just as you see them
	on the screen including date and time stamping.

	4. Help screens are available for all the featuresof
	LOADCALC PLUS.

	5. LOADCALC PLUS features both keyboard and mouse control.

	6. LOADCALC PLUS features a complete construction type
	and characteristic" database that can be accessed for
	automatic input of HEAT TRANSFER" MUTLIPLIERS for all
	 HTM fields."

	LOADCALC PLUS is very capable of handling residential, and
	within reasonable limits, many commercial applications.
	It is important to remember that all programs of this type
	are intended as design aids and are not a 100% substitute
	for throughly researching the project your involved with
	before using them tocalculate design loads.

	Make use of the help files, they should answer most
	of your questions, if however, you cannot find an answer
	to your question, or if you come upon a	problem that may
	or may not be a program bug, please feel free to call
	me and I will do my best to answer your questions and
	find a solution to any problems you have encountered.
	If you need technical support, you can call between
	the hours of 6:00 p.m. and 9:00 p.m., you can also
	obtain technical support by sending me E-Mail addressed
	atec@gglbbs.com. TECHNICAL SUPPORT WILL ONLY BE
	AVAILABLE TO REGISTERED USERS OF THE SOFTWARE, have
	your registration number ready when you call and
	reference it in any E-Mail you send. 

	As with any software program, LOADCALC PLUS is not
	exempt from having a BUG, if you find one, please let us
	know so we can attend to it immediately and provide our
	customers with a corrected copy of the program.

	LOADCALC PLUS is a BUILDING BLOCK PROGRAM, this means
	that we will continue to develope and offer ADD ON
	MODULES to expand the design capabilities of the
	software. Some future enhancements of the software will
	include individual modules for refrigeration, air-
	conditioning, and duct calcualtions, energy cost
	analysis, and more. As these offerings become
	available, we will notify all registered users of our
	new add on modules.

	GETTING STARTED

	1. Read through the help files;

	2. Aquaint yourself with the FILE, DESIGN and HELP MENUS;

	3. Fill in the AREA information FIRST, remember the
	VENTILATION and INFILTRATION FIELDS are filled in
	automatically (Ref: HTM & HTMC HELP)

	4. Fill in the requested information in the HTMC FIELDS;

	5. Fill in the DESCRIPTION and DESIGNED FOR FIELDS;

	6. Press CALCULATE;

	7. You can edit any field by DOUBLE CLICKING ON IT, then
	just type in the new information;

	8. If your designing for multiple zones SINGLE CLICK on
	DESIGN in the MENU BAR, then select the next zone to edit
	and repeat steps 1 thru 7;

	9. When you have finished SINGLE CLICK on FILE in
	the MENU BAR, you can 	now select an output to disk or
	printer.

	These few steps will get you started, however, it is highly
	recommended that you review all the help files and take some
	time to aquaint yourself with LOADCALC PLUS. Spending some
	time to learn LOADCALC PLUS will allow you to take full
 	advantage of its powerful design potential.

	Lastly, remember that LOADCALC PLUS is a WINDOWS based
	software package, it will run fine on 386 25Mhz class PC's
	and up, it will also run on slower PC's, but performance
	will be greatly degraded.Those of you familiar with WINDOWS
	and software applications running in WINDOWS already
	understand keyboard and mouse control of such programs,
	those of you that don't, READ YOUR WINDOWS MANUAL.

	Area Help

	The information requested for the area fields is
	self-explanatory.The NET FIELDS are automatically
	calculated based on information you input in the first
	seven fields under the area column.

	The VENTILATION/INFILTRATION and cooresponding HTM
	and BTUH FIELDS are automatically calculated based on
	information input in the AREA and HTMC FIELDS, refer to
	the HTM and HTMC HELP SCREENS for additional discussion on
 	determining these values.

	BTUH Help

	The BTUH FIELDS are all calculated automatically, they
	require no input on your part.

	DUCT LOSS Help

	Heat loss from ducts depends on duct C.F.M., duct size and
	shape, insulation, shape, velocity, length of the run,
	tightness of the duct construction, and temperature
	difference across the duct wall. Since none of these are
	known until after the system has been designed,	the following
	procedure is recommended:

	A. Ignore heat loss for ducts located within a conditioned space;

	B. Use the table provided when you DOUBLE CLICK on the DUCT
	LOSS HTM FIELD.

	Consult the HTM HELP SCREEN for details on selecting HTM values.

	FILE Help

	SINGLE CLICK on FILE in the MENU BAR, then SINGLE CLICK on
	OPEN / DELETE or SAVE FILE. If you select OPEN / DELETE a
	new window will open with a DIRECTORY and FILE LIST BOXES.
	You can now select a directory from the DIRECTORY LIST BOX
	by DOUBLE CLICKING on your choice, the file list will appear
	in the FILE LIST BOX on the left. SINGLE CLICK on the file
	of your choice, then SINGLE CLICK on OPEN or DELETE, the
	file will be handled according to your choice and you will
	be automatically returned to the ZONE SCREEN you were working
	on. You will also note that there is a DRIVE SELECTION WINDOW,
	SINGLE CLICKING on it will allow you to select another drive.

	Saving files is accomplished in much the same way, SINGLE
	CLICK on SAVE FILE, a window will open with DIRECTORY and
	FILE LIST BOXES, SINGLE CLICK on the directory of choice,
	now you can DOUBLE CLICK on an existing filename if you
	want to replace that file with a new edited file, it will
	appear in the FILE SAVE WINDOW, simply SINGLE CLICK on SAVE
	and the new information	will be saved to disk. If you want
	to assign a new filename, SINGLE CLICK on the FILE SAVE
	WINDOW, type in the new filename, now SINGLE CLICK on SAVE
	and your new file and its information will be saved to disk.
	As in the previous example, you can switch drives by SINGLE
	CLICKING on the DRIVE 	SELECTION WINDOW.

	One last note, only files with LOADCALC PLUS extensions
	(LJH) will be displayed.

	HTM Help

	You aquire an HTM value for input into a field by DOUBLE
	CLICKING on the HTM FIELD, a new DOUBLE WINDOW will
	appear, choose and SINGLE CLICK on a construction type in
	the window on the left, various construction descriptions
 	will appear in the window on the right,	SINGLE CLICK on the
	one that most closely matches the design characteristic of
	the structure you are working on, you will be returned to
	the ZONE you are working on and	the appropriate HTM value
	will be automatically plugged in, now simply CLICK on the
	CALCULATE BUTTON to update the design load.

	HINT: Just an information note if your trying to figure out
	the R-Value per inch of different types of insulation.

	Loose Fill machine Blown:

	Fiberglass = R2.25  - Mineral Wool = 3.125 - Cellulose = R3.7

	Loose Fill Hand Poured:

	Cellulose = R3.7 - Mineral Wool = R3.125 - Fiberglass = R2.25
	Vermiculite = R2.1

	Batts Or Blankets:

	Fiberglass = R3.14 - Mineral Wool = R3.14

	Rigid Board

	Polystyrene Beadboard = R3.6 - Extruded Polystyrene = R4.5
	Styrofoam = R5.4 Urethane = R6.2 - Fiberglass = R4.0

	HTMC Help

	Some additional explanation is necessary in this section
	for a few of the HTMC FIELDS, so we'll step through them
	one at a time.

	CEILING HEIGHT is self-explanatory.

	I.D.T. = Inside Design Temperature.

	O.D.T. = Outside Design Temperature.

	CU. FT. = Total Conditioned Interior Cubic Feet.

	A.C.H. = Air Changes Per Hour. Some additional explanation
	is in order on use of this field. There are two considerations
	with regard to Air Changes

	Per Hour:

	1) Infiltration of outside air into the conditioned environment
	based on construction characterisiticsand;

	2) make up air ventilation C.F.M to comply with your State
	Codes as they apply to the use of the building.

	The amount of infiltration is determined/estimated based on
	the overall condition and construction characteristics of
	the structure, here is a table to help you select a A.C.H
	value for infiltration.

	Floor Area   0 - 900      900 - 1500      1500 - 2100     Over 2100
        	     ______________________________________________________
	Best           0.4           0.4              0.3            0.3
	Average        1.2           1.0              0.8            0.7   
	Poor           2.2           1.6              1.2            1.0
                     ______________________________________________________
	Add For Each Fireplace       Best           Average        Poor
                                      0.1              0.2          0.6 
                     ______________________________________________________

	With regard to make up air ventilation C.F.M., you will
	have to consult your State HVAC Code, these may vary from
	state to state, so tables for ventilation C.F.M. have not
	been included in the program.

	Once you have determined the Infiltration and ventilation
	A.C.H. values, add them together and input the result in
	the A.C.H. FIELD.

	REMEMBER TO CLICK ON THE CALCULATE BUTTON IN ZONE 1 WHEN
 	YOU MAKE ANY CHANGES, ALL OTHER ZONES WILL AUTO CALCULATE.

	MODULE Help

	SINGLE CLICK on DESIGN in the MENU BAR, then SINGLE CLICK
	on either AIR-CONDITIONING or REFRIGERATION, the module you
	have selected will be loaded.

	NOTE: ONLY MODULES YOU HAVE PURCHASED WILL BE AVAILABLE.

	PRINT Help

	SINGLE CLICK on FILE in the MENU BAR, then SINGLE CLICK
	on PRINT, the PRINT WINDOW will open, check the boxes of
	the zones you wish to print, then SINGLE CLICK on the
	PRINT BUTTON. LOADCALC PLUS prints the zone forms in
	graphical format, if you are running LOADCALC PLUS on an
	older and slower computer, it will take a minute or two
	or three for the forms to be set up and sent to your
	printer, be patient, they will eventually be generated
	and they will look good too.

	ZONE Help

	LoadCalc PLUS comes equipped to handle up to 10 zones.
	You can browse 	through and edit the zones by simply clicking
	on DESIGN in the menu bar, then select the zone you wish to
	edit. As you move through the zones, the current zone will be
	displayed above the menu bar.

	Zone screen 1 can be utilized to calculate a whole structure
	design and the remaining 9 zone screens can be utilized to
	calculate individual zones within the structure, or, you can
	calculate for 10 individual zones.

	SAMPLE File

	A sample file titled HOUSE has been provided with the program
	that you can load for eaxmination.

	WARRANTY Help

	LIMITED WARRANTY

	ALL-TEMP Energy Consultants hereinafter know as ATEC warrants
	that:

	1. The material of the software disk(s) and the documentation
	are not defective;

	2. The program is properly recorded on the disk(s);

	3. The on line documentation is substantailly complete and
	contains all the information ATEC deems necessary to use
	the software;

	4. The program(s) functions substantially as described in
	the documentation. The sole remedy for breach of this
	limited warranty is replacement of the defective product.
	This limited warranty is for one year from the date of purchase
	of the software and is extended only to the first year of the
	software. To replace a defective disk(s) during the warranty
	term, send the defective disk(s) and proof of registration
	(YOUR REGISTRATION #) to:

	ALL-TEMP Energy Consultants
	620 Harding Street Waupaca, Wisconsin  54981

	To replace a disk(s) damaged during the warranty term, or
	damaged for any reason whatsoever following the warranty
	term, send your name and address along with the defective
	disk(s) and $7.50 to the above address. The foregoing
	replacement policy applies only to the original registered
	user of the software.
	
	Except as provided above, and subject to any contrary
	provisions of applicable law, ATEC disclaims any and
	all implied warranties, including warranties of
	merchantability and fitness for a particular purpose, and
	any warranty coverage for incidental or consequential
	damages.


	UPDATES

	NO, updated modules WILL NOT BE FREE to registered users,
	however, they will be made available to registered users for
	$39.95 plus shipping and handling.

	Updated modules will only be made available when warranted
	by significant changes in the software features.

	EMAIL

	My email address is: atec@gglbbs.com


	SHAREWARE DOWNLOAD

	You may download the Unregistered Shareware Version of
	LoadCalc Plus from our WEB Site at:

	http://www.gglbbs.com/atec

	You mail also send me E-mail at:

	atec@gglbbs.com

	

	Robert W. Krueger, Author