   Banyan 5.53 NDIS Workstation
                                                                    v2.01
      
      
      Banyan* NDIS workstation installation notes for Artisoft's
      NodeRunner Pro(TM) LAN adapters
      ==========================================================
         
         Location of Driver:     \NDIS\EPRO.DOS
         
      
      Sample Configuration Files
      --------------------------
      
      CONFIG.SYS (will contain):
         
         DEVICE=C:\BAN\PROTMAN.DOS /I:C:\BAN
         DEVICE=C:\BAN\EPRO.DOS
      
      PROTOCOL.INI:
         
         [EPRO_NIF]
            Drivername = EPRO$
            IOADDRESS = 0x300
      
      
      General Installation
      --------------------
      
      1  The NodeRunner Pro LAN adapter uses a NDIS 2.0.1 driver to
         connect to a Banyan server.  If you have a NDIS client disk
         prepared, skip to step #6.
      
      2  To generate a NDIS client disk, run PCCOPY which is located on
         the Z drive of the Banyan server.
      
      3  Choose PC Configuration Software and/or LAN driver, and select
         NDIS Ethernet.
      
      4  Choose the appropriate DOS redirector (example: REDIRALL for all
         versions of DOS).
      
      5  Specify directory of where you want the client software copied
         to.  The default is A:\.
      
      6  On the client you wish to setup, copy the NDIS client software
         to a directory on the hard drive.  Run Banyan's PCCONFIG
         program.  Select Network Card Settings and page down to select
         the NDIS Ethernet option.  Specify the Interrupt (as set in
         NProSet) and the PROTOCOL.INI Bindings parameter: EPRO_NIF.
      
      7  Select Login Environment Settings, then Select Default
         Communications Driver.  Page down to the NDIS Ethernet option
         and select it.
      
      8  Save settings before exiting PCCONFIG.
      
      9  Copy the files PROTOCOL.INI and EPRO.DOS that are located in the
         NDIS subdirectory of the NodeRunner Pro LAN adapter disk to
         the BAN subdirectory (as per the example) or other directory
         where Banyan client files are.  Modify the PROTOCOL.INI file and
         remove the semi-colon in front of [EPRO_NIF] and change the
         IOAddress of the adapter to match the setting in NProSet.
      
      10 Add the lines to your CONFIG.SYS file as indicated above.
      
      11 Reboot and run BAN to attach to the Banyan server.
      
      
      Hints and Tips
      --------------
      
      1  Error Message with PRO0025E:
      
         This type of message will occur when the driver attempts to bind
         to the protocol manager.  It generally indicates that there's a
         syntax or other error in the PROTOCOL.INI file.  Review the file
         carefully for errors.  Also, verify parameters entered in
         PCCONFIG.  For additional information, reference NDISBAN.DOC,
         which is part of the NDIS Banyan client software.
      
      2  Make sure your NDISBAN.COM is dated April 1994 or later.
         Earlier versions may not work properly.
      
      3  Parameters for the PROTOCOL.INI file:
      
         DRIVERNAME: This is the one required parameter.  See example at
         the top of this document for syntax.
      
         IOADDRESS: This is the base I/O address for the NodeRunner Pro
         adapter.  If you are using multiple boards in one machine, make
         sure you specify the correct IOADDRESS for each board.
      
         INTERRUPT (optional): This is the system interrupt that the
         adapter uses.  If a value is specified and it is different from
         what the card is currently set to, this parameter will OVERRIDE
         whatever is in the EEPROM.
      
      
      
      *  Third-party trademarks are the property of their respective
         owners
