The following text describes problems and solutions that have been
encountered when installing Lisa. Some of the information is provided 
courtesy of T&J Software. They are not related to ChAoS Online or to 
Chat With Lisa, but they do use the same DoorFrame software as Lisa. 

MY REGISTRATION CODE DOESN'T WORK
=================================
* The #1 reason for not working: The names in the LISA.CFG file do not
  match the names (spelling) on your registration form. If you registered 
  by mail, double-check the BBS name and the SYSOP name on the form we 
  sent you. If you registered online, call ChAoS and double-check the 
  names by selecting "Display Door Code" from the Purchase Menu. 
   
* Other reasons the code might not work: The code entered in LISA.CFG was
  typed wrong or has spaces in it; or LISA.CFG was renamed. (see below). 
  
THE SETTINGS IN MY CONFIG FILE HAVE NO EFFECT
=============================================
* Lisa always gets her settings from the LISA.CFG file. Did you change
  the name or create multiple .CFG files? Change the filename back to 
  LISA.CFG and edit the settings there. If your BBS has multiple nodes, 
  read the MULTIPLE NODES section of the SYSOP.TXT file. 

THE LOCAL SCREEN DISPLAY IS GARBAGE
===================================
* This is almost always caused by ANSI not being installed. You need
  to add the following line to your CONFIG.SYS file:
     DEVICE=C:\DOS\ANSI.SYS
  Reboot the machine after adding the line. Read your DOS manual 
  for more information about the ANSI.SYS screen driver. 

* If you are multi-tasking with DesqView, do the following instead: 
  Add DVANSI.COM to the batch file for each node.

LOCKUPS ON CERTAIN COM PORTS or GARBLED INFORMATION ON REMOTE
=============================================================
* If the remote terminal cannot receive, or the screen is garbled, 
  you are probably using a non-standard IRQ. Make sure you are 
  passing the correct IRQ value to the door in the batch file. 
  Example:  LISA LISA.CFG /5
  
* If you are using a multi-port board with a fossil driver, use
  the following:  LISA LISA.CFG /FD 
  Please read SYSOP.TXT for complete information.
  
DOOR.SYS PROBLEMS or `OUT OF STRING SPACE' ERRORS
=================================================
* Problems may develop when using the DOOR.SYS drop file if you have 
  a large number of conferences. Due to the specifications of DOOR.SYS, 
  all the conferences that a user is "joined to" are written to line 
  #23 of DOOR.SYS. This may cause the DOOR.SYS file to become too large, 
  which usually results in the "out of string space" error.
  
* WildCat 4.0 users should download a file called FDOORSYS.ZIP written 
  by Tim Rider (call The Source BBS at 310-371-3737). This small utility 
  will remove the offending line in DOOR.SYS.
  
* Wildcat 4.01+ users can go to the MakeWild Doors Menu and change the 
  door setup to use a "small" DOOR.SYS drop file.
  
* PCBoard users should use the PCBOARD.SYS drop file.

KEYBOARD TIMEOUTS AND 486DX COMPUTERS
=====================================
* If you are using a 486DX computer and keep getting "keyboard timeout"
  errors, or ERROR 5 or 6, you need to place the following line in your 
  AUTOEXEC.BAT file:
  
  SET NO87=ON

  This will turn off your math co-processor and allow the door to 
  function properly.

OVERFLOW ERRORS
===============
* Overflows can occur if you are running under DesqView and your tick
  counts are set too low -- try raising the tick counts.

* If you're running Wildcat! v3.9+ and are getting OVERFLOW errors,
  make sure NONE of your security level definitions have the MAXIMUM
  DAILY DOWNLOADS set to more than 32,000 -- anything over that will
  cause an OVERFLOW ERROR in any door using DOORFRAME.

GRAPHIC CARDS (general)
=======================
* ATI Graphics Ultra Pro card - do not use the ANSI.SYS driver that
  came with the card. Use the normal DOS ANSI.SYS for the screens
  to show correctly.

* Trident SVGA Cards - You should have a utility disk with a file
  called TANSI.SYS, use this ansi driver instead of DOS ANSI.SYS.

DESQVIEW/X
==========
* Make sure you have the MATH COPROCESSOR flagged ON even if you 
  don't have a math coprocessor.

REMOTE ACCESS v2.0+
===================
* Using DOOR.SYS may result in an OVERFLOW error -- try using a
  different caller drop file such as DORINFO1.DEF. This is currently
  being examined!

RENEGADE BBS
============
* If you are using the BNU fossil driver and having problems with doors, 
  try using X00 v1.50+. Several Renegade systems have reported problems 
  using BNU with doors.
  
* If you are getting out-of-memory errors, go into the System Config
  section, [E] System Toggles, then [U] to turn the SWAP FILE 'ON'.

SPITFIRE BBS's
==============
* If you're having trouble with the door dropping carrier on exiting
  back to the BBS, switch to using DOOR.SYS instead of SFDOORS.DAT. 
  This happens on some Spitfire configurations when using SFDOORS.DAT.

TRIBBS v5.02+
=============
* Color ANSI checking will not work if you use TRIBBS.SYS drop file.
  Set the doors up using the PCBOARD.SYS drop file.

* If you use DOOR.SYS, TriBBS reloads this file and will deduct twice
  the amount of time that was actually used. Try using another drop
  file, or copying the DOOR.SYS to a separate directory and then
  telling the door to look there for it.

* NOTE: This only applies to doors where you adjust the user's time 
        in the door such as Bordello, Studs, and Studette.

WILDCAT! 3.X
============
* You must use the caller drop file DOOR.SYS to make sure the callers 
  remaining time is passed back to Wildcat.

* Wildcat! IM Version Setup using DigiFossil v2.x:

  All T&J doors will run on the Wildcat! IM version using DigiFossil
  v2.x. I have received TWO different setup routines concerning the
  IM version, here's an example:

  DF LOCK%WCNODEID%          -OR-       DF ON
  CD\DOORS\GAME                         CD\DOORS\GAME
  GAME GAME.CFG /FD                     GAME GAME.CFG
  CD\WC30                               CD\WC30
  DF OFF                                DF OFF

SOME QUICKBASIC ERROR CODES (DOORFRAME USES THE SAME CODES)
===========================================================
 2   Syntax error                       61   Disk full
 5   Illegal function call              62   Input past end of file
 6   Overflow                           63   Bad record number
 7   Out of memory                      64   Bad filename
11   Division by zero                   67   Too many files
13   Type mismatch                      68   Device unavailable
24   Device timeout                     69   Comm-buffer overflow
25   Device fault                       70   Permission denied
52   Bad filename or number             71   Disk not ready
53   File not found                     72   Disk media error
55   File already open                  74   Rename across disk
57   Device I/O error                   75   Path/File access error
58   File already exists                76   Path not found
59   Bad record length

Error #53 can be caused by a missing LISA.CFG or LISA.DAT file, or the
program cannot find the BBS drop file. Error #62 is usually caused by 
the LISA.CFG file not having enough lines. Error #75/76 usually results