Ofoto(TM) for Windows(TM), Version 1.02 September 2, 1993


Installing Ofoto
----------------

Before installing Ofoto be sure you have followed the manufacturer's
instructions for installing both your scanner board and the software
supplied with it.

Note: If you use anything other than default settings for your board
(i.e. if you change the board's port address), you may need to modify
your config.sys file or your Ofoto configuration.  See the scanner
information section at the end of the Readme.

For Ofoto installation instructions, see the "Installing Ofoto for 
Windows" card included in your package.

Ofoto runs best when your CONFIG.SYS file sets Files to at least 40 
and Buffers to at least 10. When you install Ofoto, the Installer 
checks these settings in your CONFIG.SYS file. If your Files or Buffer 
settings are lower, you can choose to have the Installer change them 
automatically.  

If you choose not to have the Installer automatically update your 
CONFIG.SYS file, you must update the file manually. To find out what 
changes to make, refer to the file CONFIG.OFO in your Ofoto 
directory. CONFIG.OFO is placed in your Ofoto directory only when 
you choose not to have the Installer automatically update your 
CONFIG.SYS file.

Exporting a calibration
-----------------------
Calibrations are stored in the Ofoto directory in files with a ".CAL"
extension.  The Ofoto.ini file defines what calibration names are
associated with what ".CAL" files.  Under the "[ofotoCalibrations]"
heading there is a definition line for each custom calibration.  To
take the calibration to another computer, copy both the ".CAL" file
and the line describing that calibration from the Ofoto.ini file to
the other computer.  Put the ".CAL" in the Ofoto directory and update
the Ofoto.ini file with the line describing the calibration.

Installing a new scanner
------------------------
If you wish to install a new scanner, follow these steps:

1. Carefully read the manufacturer instructions for your scanner and 
install the new scanner with the supplied software. 
2. Run Ofoto and select "Run Scanner Setup, Try Again" from the 
Scanner Initialization window.
3. Select "Add scanner" and insert Disk 1.
4. Select the correct scanner from the list and select O.K.
You will need to follow these steps even when changing between
different models in the same family of scanners (i.e. the HP ScanJet
IIc to the HP ScanJet IIp) in order to attain the highest quality
images from each model scanner.

Printing on a PostScript printer 
--------------------------------
IMPORTANT: If you are printing from a PostScript printer, you must
select the correct printer setup options in Windows 3.0 and 3.1. 

For Windows 3.0:
1. Open the Control Panels icon
2. Open Printers
3. Click Configure
4. Set Device Not Seleted Time-out to 999 and Transmission Retry
Time-out to 999.
5. Click Setup
6. Click Options 
7. Set Job Time-out to 0 seconds

For Windows 3.1:
1. Open the Control Panels icon
2. Open Printers
3. Click Connect
4. Set Device Not Seleted Time-out to 999 and Transmission Retry
Time-out to 999.
5. Click Network
6. Click Options
7. Set Job Time-out to 0 seconds

Printing on an Apple LaserWriter IIg
------------------------------------
To print with PhotoGrade quality on an Apple LaserWriter IIg that has
5MB of RAM, you must set Paper Size to "Letter Small" in Windows.

If you see an "Invalid Gray Chart" message
------------------------------------------
When scanning a gray chart to calibrate Ofoto for your printer, Ofoto
may display an "Invalid Gray Chart" message. This occurs when some
portion of the gray chart cannot be scanned because the chart is
placed incorrectly either on the page or on the scanner.

The chart should be centered on the page with at least a one inch
white margin around the edge of the paper. Consult the manual for
the application used to print the chart to see how to do this.

To correctly place the chart on the scanner:

1. Check the Ofoto document window to see which portion of the chart
was not scanned (the outermost black border should be scanned by the
first pass).
2. Move the chart so that the outermost black border will be scanned.
3. Scan the chart again. 

Using Ofoto with Ventura Publisher 3.0
--------------------------------------
Ventura Publisher 3.0 inverts 8-bit Ofoto images. If you experience 
this problem, you may wish to upgrade your Ventura Publisher software.
Ventura Publisher version 4.0 works properly with Ofoto images.

Using Ofoto with Aldus Freehand and PageMaker 4.0
-------------------------------------------------
Aldus Freehand and PageMaker 4.0 do not accept 8-bit PCX images. To 
import Ofoto images into Aldus Freehand and PageMaker 4.0 use the
TIFF file format when saving images in Ofoto.

Opening a non-PostScript image
------------------------------
If you scan and save an image using a non-postscript calibration,
Ofoto scans the image at 8 bits but saves it as a 1-bit halftoned 
image. Consequently, when you open the saved image, a 1-bit image is
displayed and thus will appear as if it contains "cross-hatch"
patterns. 

Calibrating for a Printer that is not listed
--------------------------------------------
If you are calibrating Ofoto for a printer that is not listed in the 
Scan Controls Calibration window, consult your printer manual for the 
DPI (dots per inch) of your printer. Then, follow these steps:

1. Select Calibrate/Create Gray Chart
2. Base the calibration on any printer. If you know of one similar to
your printer, select it.
3. Select Options, change the printer dpi field to the specified dpi
for your printer, and select a name.
4. Select Print Gray Chart and O.k.
5. Once you scan in the printed gray chart, your new calibration will
be listed for your printer in the Scan Controls.


If your filenames do not appear in the file save window
-------------------------------------------------------
If your filenames are missing from the file selection list when 
saving a file, check the shade of gray you have selected for the
window text.  Files listed in the selection box are grayed out when
saving a file.  If the shade of gray you have selected is the same 
shade as the grayed out text, your filenames will not appear.

If you see a "Scanner communication error" message
--------------------------------------------------
Follow the directions in the error message. Additionally, some models
of scanners need to be powered on before the computer boots to allow
the scanner driver to load properly.

Scanner configuration summary
-----------------------------
This section summarizes the configuration information provided by each
scanner manufacturer and contains some additional information about
configuring for use with Ofoto.  If you follow the manufacturer's
instructions for installing the scanner hardware and software and then
install Ofoto this information should not be needed, but it may help if
you have problems getting Ofoto to work with the scanner the first time.

Apple OneScanner
    Board:
        Adaptec AHA-1510 SCSI board.
    Cable:
        50-pin SCSI to 50-pin SCSI.  (Same as Mac SCSI to SCSI cable).
        Terminator required.
    Config line if default jumper settings:
        device=c:\ofoto\aspi2dos.sys /Z /U-
    Ofoto driver files:
        apple.pxw
        appleone.scn
    Possible conflicts:
        Interrupt:
            12   Jumper I2
            11   Jumper I1    (default)
            10   Jumper I0
            9    Jumper I9
            Any change requires use of /Qx option for aspi2dos config
            line where 'x' is the 1 or 2 digit interrupt number.
        I/O address:
            340H - 35EH No jumper AL (default)
            140H - 15EH Jumper AL
            Changing to 140H requires use of /P140 option for aspi2dos
            config line.

Epson 300c (or LaCie Silverscan)
    Board:
        EPSON Bi-directional Parallel Interface Board B808011.
    Cable:
        Printer cable (DB25 male to Centronics 36-pin).
    Config line for any jumper settings:
        None required.
    Ofoto driver files:
        epsn300c.pxw
        epsn300c.scn
    Possible conflicts:
        Interrupt:
            IRQ 5        Jumper J2 set to IRQ 5 (default)
            IRQ 7        Jumper J2 set to IRQ 7
        I/O address:
            378H - 37AH  Jumper J1 set to LPT1
            278H - 27AH  Jumper J1 set to LPT2 (default)

HP ScanJet
    Board:
        HP ScanJet / ScanJet Plus parallel interface board.
    Cable:
        Like printer cable (DB25 male to Centronics 36-pin).
        Includes grounding wire to be connected to scanner.
    Config line for any jumper settings:
        device=c:\ofoto\sjdriver.sys
    Ofoto driver files:
        scanjet.pxw
        hpscjet.scn
    Possible conflicts:
        Memory address:
            C0000 - C3FFF  (switch 2, 3, 4 as 0 0 0)
            C4000 - C7FFF  (switch 2, 3, 4 as 1 0 0)
            C8000 - CBFFF  (switch 2, 3, 4 as 0 1 0)
            CC000 - CFFFF  (switch 2, 3, 4 as 1 1 0)
            D0000 - D3FFF  (switch 2, 3, 4 as 0 0 1)
            D4000 - D7FFF  (switch 2, 3, 4 as 1 0 1)
            D8000 - DBFFF  (switch 2, 3, 4 as 0 1 1)
            DC000 - DFFFF  (switch 2, 3, 4 as 1 1 1)
        I/O address:
            278H - 27FH    (switch 1 set as 0)
            268H - 26FH    (switch 1 set as 1)

HP ScanJet IIc
    Board:
        HP SCSI board.  Same as for HP Scanjet IIp.
    Cable:
        25-pin DB25 male to 50-pin SCSI.  (Same as Mac to SCSI cable).
        Terminator required.
    Config line for any jumper settings:
        device=c:\ofoto\sjii.sys
    Ofoto driver files:
        scanjet.pxw
        hpscjt2c.scn
    Possible conflicts:
        Memory address:
            (switch 1 always 1 - open )
            C8000 - CBFFF    (switch 2, 3, 4 as 1 1 0)
            CC000 - CFFFF    (switch 2, 3, 4 as 0 1 0)
            D0000 - D3FFF    (switch 2, 3, 4 as 1 0 0)
            D4000 - D7FFF    (switch 2, 3, 4 as 0 0 0)
            D8000 - DBFFF    (switch 2, 3, 4 as 1 1 1)
            DC000 - DFFFF    (switch 2, 3, 4 as 0 1 1)
            E0000 - E3FFF    (switch 2, 3, 4 as 1 0 1)
            E4000 - E7FFF    (switch 2, 3, 4 as 0 0 1)

HP ScanJet IIp
    Board:
        HP SCSI board.  Same as for HP Scanjet IIc.
    Cable:
        25-pin DB25 male to 50-pin SCSI.  (Same as Mac to SCSI cable).
        Terminator required.
    Config line for any jumper settings:
        device=c:\ofoto\sjii.sys
    Ofoto driver files:
        scanjet.pxw
        hpscjt2p.scn
    Possible conflicts:
        Memory address:
            (switch 1 always 1 - open )
            C8000 - CBFFF    (switch 2, 3, 4 as 1 1 0)
            CC000 - CFFFF    (switch 2, 3, 4 as 0 1 0)
            D0000 - D3FFF    (switch 2, 3, 4 as 1 0 0)
            D4000 - D7FFF    (switch 2, 3, 4 as 0 0 0)
            D8000 - DBFFF    (switch 2, 3, 4 as 1 1 1)
            DC000 - DFFFF    (switch 2, 3, 4 as 0 1 1)
            E0000 - E3FFF    (switch 2, 3, 4 as 1 0 1)
            E4000 - E7FFF    (switch 2, 3, 4 as 0 0 1)

HP ScanJet Plus
    Board:
        HP ScanJet / ScanJet Plus parallel interface board.
    Cable:
        Like printer cable (DB25 male to Centronics 36-pin).
        Includes grounding wire to be connected to scanner.
    Config line for any jumper settings:
        device=c:\ofoto\sjdriver.sys
    Ofoto driver files:
        scanjet.pxw
        hpscjetp.scn
    Possible conflicts:
        Memory address:
            C0000 - C3FFF  (switch 2, 3, 4 as 0 0 0)
            C4000 - C7FFF  (switch 2, 3, 4 as 1 0 0)
            C8000 - CBFFF  (switch 2, 3, 4 as 0 1 0)
            CC000 - CFFFF  (switch 2, 3, 4 as 1 1 0)
            D0000 - D3FFF  (switch 2, 3, 4 as 0 0 1)
            D4000 - D7FFF  (switch 2, 3, 4 as 1 0 1)
            D8000 - DBFFF  (switch 2, 3, 4 as 0 1 1)
            DC000 - DFFFF  (switch 2, 3, 4 as 1 1 1)
        I/O address:
            278H - 27FH    (switch 1 set as 0)
            268H - 26FH    (switch 1 set as 1)

Microtek 300G
    Board:
        MS-PCY Interface Card.
    Cable:
        25-pin DB25 male to 25-pin DB25 female.
    Config line for any jumper settings:
        device=c:\ofoto\mscan.sys
    Ofoto driver files:
        mktk_at.pxw
        mktk300g.scn
    Possible conflicts:
        I/O address:
            100H - 10FH    (switch 1, 2, 3, 4, 5, 6 set as 1 0 1 1 1 1)
            120H - 12FH    (switch 1, 2, 3, 4, 5, 6 set as 1 0 1 1 0 1)
            200H - 20FH    (switch 1, 2, 3, 4, 5, 6 set as 0 1 1 1 1 1)
            220H - 22FH    (switch 1, 2, 3, 4, 5, 6 set as 0 1 1 1 0 1)
            300H - 30FH    (switch 1, 2, 3, 4, 5, 6 set as 0 0 1 1 1 1)
                           300H is default
            320H - 32FH    (switch 1, 2, 3, 4, 5, 6 set as 0 0 1 1 0 1)
            The correct address needs to be selected in the scanner
            configuration dialog box in Ofoto.

Microtek 300Z
    Board:
        MS-PCY Interface Card.
    Cable:
        25-pin DB25 male to 25-pin DB25 female.
    Config line for any jumper settings:
        device=c:\ofoto\mscan.sys
    Ofoto driver files:
        mktk_at.pxw
        mktk300z.scn
    Possible conflicts:
        I/O address:
            100H - 10FH    (switch 1, 2, 3, 4, 5, 6 set as 1 0 1 1 1 1)
            120H - 12FH    (switch 1, 2, 3, 4, 5, 6 set as 1 0 1 1 0 1)
            200H - 20FH    (switch 1, 2, 3, 4, 5, 6 set as 0 1 1 1 1 1)
            220H - 22FH    (switch 1, 2, 3, 4, 5, 6 set as 0 1 1 1 0 1)
            300H - 30FH    (switch 1, 2, 3, 4, 5, 6 set as 0 0 1 1 1 1)
                           300H is default
            320H - 32FH    (switch 1, 2, 3, 4, 5, 6 set as 0 0 1 1 0 1)
            The correct address needs to be selected in the scanner
            configuration dialog box in Ofoto.

Microtek 600G
    Board:
        MS-PCY Interface Card.
    Cable:
        25-pin DB25 male to 25-pin DB25 female.
    Config line for any jumper settings:
        device=c:\ofoto\mscan.sys
    Ofoto driver files:
        mktk_at.pxw
        mktk600g.scn
    Possible conflicts:
        I/O address:
            100H - 10FH    (switch 1, 2, 3, 4, 5, 6 set as 1 0 1 1 1 1)
            120H - 12FH    (switch 1, 2, 3, 4, 5, 6 set as 1 0 1 1 0 1)
            200H - 20FH    (switch 1, 2, 3, 4, 5, 6 set as 0 1 1 1 1 1)
            220H - 22FH    (switch 1, 2, 3, 4, 5, 6 set as 0 1 1 1 0 1)
            300H - 30FH    (switch 1, 2, 3, 4, 5, 6 set as 0 0 1 1 1 1)
                           300H is default
            320H - 32FH    (switch 1, 2, 3, 4, 5, 6 set as 0 0 1 1 0 1)
            The correct address needs to be selected in the scanner
            configuration dialog box in Ofoto.

Microtek 600Z
    Board:
        MS-PCY Interface Card.
    Cable:
        25-pin DB25 male to 25-pin DB25 female.
    Config line for any jumper settings:
        device=c:\ofoto\mscan.sys
    Ofoto driver files:
        mktk_at.pxw
        mktk600z.scn
    Possible conflicts:
        I/O address:
            100H - 10FH    (switch 1, 2, 3, 4, 5, 6 set as 1 0 1 1 1 1)
            120H - 12FH    (switch 1, 2, 3, 4, 5, 6 set as 1 0 1 1 0 1)
            200H - 20FH    (switch 1, 2, 3, 4, 5, 6 set as 0 1 1 1 1 1)
            220H - 22FH    (switch 1, 2, 3, 4, 5, 6 set as 0 1 1 1 0 1)
            300H - 30FH    (switch 1, 2, 3, 4, 5, 6 set as 0 0 1 1 1 1)
                           300H is default
            320H - 32FH    (switch 1, 2, 3, 4, 5, 6 set as 0 0 1 1 0 1)
            The correct address needs to be selected in the scanner
            configuration dialog box in Ofoto.

Microtek ScanMaker II
    Board:
        MS-PCZ SCSI Interface Card.
    Cable:
        25-pin DB25 male to 50-pin SCSI.  (Same as Mac to SCSI cable).
        Terminator required.
    Config line for any jumper settings:
        device=c:\ofoto\mscsi.sys
    Ofoto driver files:
        scnmkrii.pxw
        mktksmii.scn
    Possible conflicts:
        Interrupt:
            Non-IRQ        jumper J2 1, 2 set as out, out (default)
            IRQ 5          jumper J2 1, 2 set as  in, out
            IRQ 7          jumper J2 1, 2 set as out, in
        Memory address:
            C8000 - CBFFF  jumper J1 1, 2, 3 set as  in, out, out
            CC000 - CFFFF  jumper J1 1, 2, 3 set as  in, out,  in
            D0000 - D3FFF  jumper J1 1, 2, 3 set as  in,  in, out
            D4000 - D7FFF  jumper J1 1, 2, 3 set as  in,  in,  in (default)
            D8000 - DBFFF  jumper J1 1, 2, 3 set as out, out, out
            DC000 - DFFFF  jumper J1 1, 2, 3 set as out, out,  in
            E0000 - E3FFF  jumper J1 1, 2, 3 set as out,  in, out
            E4000 - E7FFF  jumper J1 1, 2, 3 set as out,  in,  in
            The correct address needs to be selected in the scanner
            configuration dialog box in Ofoto.


Ricoh IS50
    Board:
        Adaptec ASPI compatible SCSI board.  For the AHA-1510 conflicts
        and jumpers see the Apple OneScanner setup.
        Adaptec AHA-1540 or AHA-1542 SCSI board suggested.
    Cable:
        50-pin SCSI to 50-pin SCSI.  (Same as Mac SCSI to SCSI cable).
        Terminator required.
    Config line if default jumper settings:
        device=c:\ofoto\aspi4dos.sys
    Ofoto driver files:
        ricoh560.pxw
        ricoh50.scn
    Possible conflicts:
        Jumpers shown are for 1540B/1542B card,
            1540C/1542C card requires software setup.
            Jumper installed = 1, not installed = 0.
        Memory address if BIOS enabled, jumper J6-1 installed (default):
            C8000 - CBFFF  jumper J7 7, 8 set as 1, 1
            CC000 - CFFFF  jumper J7 7, 8 set as 1, 0
            D8000 - DBFFF  jumper J7 7, 8 set as 0, 1
            DC000 - DFFFF  jumper J7 7, 8 set as 0, 0 (default)
        DMA:
            0  jumper J5 7-8, J9 1-8 set 1, 1, 1, 0, 0, 0, 1, 0, 0, 0
            5  jumper J5 7-8, J9 1-8 set 0, 1, 0, 1, 0, 0, 0, 1, 0, 0 (default)
            6  jumper J5 7-8, J9 1-8 set 1, 0, 0, 0, 1, 0, 0, 0, 1, 0
            7  jumper J5 7-8, J9 1-8 set 0, 0, 0, 0, 0, 1, 0, 0, 0, 1
        Interrupt:
            9  jumper J5 9-11 set as 0, 0, 0
            10 jumper J5 9-11 set as 1, 0, 0
            11 jumper J5 9-11 set as 0, 1, 0 (default)
            12 jumper J5 9-11 set as 1, 1, 0
            14 jumper J5 9-11 set as 0, 0, 1
            15 jumper J5 9-11 set as 1, 0, 1
        I/O address:
            130H - 133H  jumper J7 2-4 set as 1, 0, 1
            134H - 137H  jumper J7 2-4 set as 0, 0, 1
            230H - 233H  jumper J7 2-4 set as 1, 1, 0
            234H - 237H  jumper J7 2-4 set as 0, 1, 0
            330H - 333H  jumper J7 2-4 set as 1, 0, 0 (default)
            334H - 337H  jumper J7 2-4 set as 0, 0, 0
            Changing from 330H requires use of /P<address> option for
            aspi4dos config line (eg /P230).

Ricoh IS60
    Board:
        Adaptec ASPI compatible SCSI board.  For the AHA-1510 conflicts
        and jumpers see the Apple OneScanner setup.
        Adaptec AHA-1540 or AHA-1542 SCSI board suggested.
    Cable:
        50-pin SCSI to 50-pin SCSI.  (Same as Mac SCSI to SCSI cable).
        Terminator required.
    Config line if default jumper settings:
        device=c:\ofoto\aspi4dos.sys
    Ofoto driver files:
        ricoh560.pxw
        ricoh60.scn
    Possible conflicts:
        Jumpers shown are for 1540B/1542B card,
            1540C/1542C card requires software setup.
            Jumper installed = 1, not installed = 0.
        Memory address if BIOS enabled, jumper J6-1 installed (default):
            C8000 - CBFFF  jumper J7 7, 8 set as 1, 1
            CC000 - CFFFF  jumper J7 7, 8 set as 1, 0
            D8000 - DBFFF  jumper J7 7, 8 set as 0, 1
            DC000 - DFFFF  jumper J7 7, 8 set as 0, 0 (default)
        DMA:
            0  jumper J5 7-8, J9 1-8 set 1, 1, 1, 0, 0, 0, 1, 0, 0, 0
            5  jumper J5 7-8, J9 1-8 set 0, 1, 0, 1, 0, 0, 0, 1, 0, 0 (default)
            6  jumper J5 7-8, J9 1-8 set 1, 0, 0, 0, 1, 0, 0, 0, 1, 0
            7  jumper J5 7-8, J9 1-8 set 0, 0, 0, 0, 0, 1, 0, 0, 0, 1
        Interrupt:
            9  jumper J5 9-11 set as 0, 0, 0
            10 jumper J5 9-11 set as 1, 0, 0
            11 jumper J5 9-11 set as 0, 1, 0 (default)
            12 jumper J5 9-11 set as 1, 1, 0
            14 jumper J5 9-11 set as 0, 0, 1
            15 jumper J5 9-11 set as 1, 0, 1
        I/O address:
            130H - 133H  jumper J7 2-4 set as 1, 0, 1
            134H - 137H  jumper J7 2-4 set as 0, 0, 1
            230H - 233H  jumper J7 2-4 set as 1, 1, 0
            234H - 237H  jumper J7 2-4 set as 0, 1, 0
            330H - 333H  jumper J7 2-4 set as 1, 0, 0 (default)
            334H - 337H  jumper J7 2-4 set as 0, 0, 0
            Changing from 330H requires use of /P<address> option for
            aspi4dos config line (eg /P230).

Ricoh IS410
    Board:
        Adaptec AHA-1540 or AHA-1542 SCSI board.
    Cable:
        50-pin SCSI to 50-pin SCSI.  (Same as Mac SCSI to SCSI cable).
        Terminator required.
    Config line if default jumper settings:
        device=c:\ofoto\aspi4dos.sys
    Ofoto driver files:
        ricoh410.pxw
        ricoh410.scn
    Possible conflicts:
        Jumpers shown are for 1540B/1542B card,
            1540C/1542C card requires software setup.
            Jumper installed = 1, not installed = 0.
        Memory address if BIOS enabled, jumper J6-1 installed (default):
            C8000 - CBFFF  jumper J7 7, 8 set as 1, 1
            CC000 - CFFFF  jumper J7 7, 8 set as 1, 0
            D8000 - DBFFF  jumper J7 7, 8 set as 0, 1
            DC000 - DFFFF  jumper J7 7, 8 set as 0, 0 (default)
        DMA:
            0  jumper J5 7-8, J9 1-8 set 1, 1, 1, 0, 0, 0, 1, 0, 0, 0
            5  jumper J5 7-8, J9 1-8 set 0, 1, 0, 1, 0, 0, 0, 1, 0, 0 (default)
            6  jumper J5 7-8, J9 1-8 set 1, 0, 0, 0, 1, 0, 0, 0, 1, 0
            7  jumper J5 7-8, J9 1-8 set 0, 0, 0, 0, 0, 1, 0, 0, 0, 1
        Interrupt:
            9  jumper J5 9-11 set as 0, 0, 0
            10 jumper J5 9-11 set as 1, 0, 0
            11 jumper J5 9-11 set as 0, 1, 0 (default)
            12 jumper J5 9-11 set as 1, 1, 0
            14 jumper J5 9-11 set as 0, 0, 1
            15 jumper J5 9-11 set as 1, 0, 1
        I/O address:
            130H - 133H  jumper J7 2-4 set as 1, 0, 1
            134H - 137H  jumper J7 2-4 set as 0, 0, 1
            230H - 233H  jumper J7 2-4 set as 1, 1, 0
            234H - 237H  jumper J7 2-4 set as 0, 1, 0
            330H - 333H  jumper J7 2-4 set as 1, 0, 0 (default)
            334H - 337H  jumper J7 2-4 set as 0, 0, 0
            Changing from 330H requires use of /P<address> option for
            aspi4dos config line (eg /P230).

UMAX UG630
UMAX UC630 ROM 2.4  /  ENV 6100 ROM 2.4
UMAX UC630 ROM 2.6  /  ENV 6100 ROM 2.6
UMAX UC840 ROM 1.2
UMAX UC840 ROM 1.4  /  ENV 8100 ROM 1.4
UMAX UC1260         /  ENV 24 PRO
    Board:
        UMAX GSII SCSI Adapter Board.
    Cable:
        25-pin SCSI to 50-pin SCSI.  (Same as Mac SCSI to SCSI cable).
        Terminator required.
    Config line if default jumper settings:
        device=c:\ofoto\umax.sys
    Ofoto driver files:
        All scanners use:
             umaxgsii.pxw
        UMAX 630 ROM 2.4     ENV 6100 ROM 2.4
             uc630_24.scn         en630_24.scn
        UMAX 630 ROM 2.6     ENV 6100 ROM 2.6
             uc630_26.scn         en630_26.scn
        UMAX 840 ROM 1.2     ENV 8100 ROM 1.2
             uc840_12.scn         en840_12.scn
        UMAX 840 ROM 1.4     ENV 8100 ROM 1.4
             uc840_14.scn         en840_14.scn
        UMAX 1260            ENV 24 PRO
             uc1260.scn           en1260.scn
    Possible conflicts:
        Interrupt:
            9  jumper JP4
            5  jumper JP3
            4  jumper JP2
            3  jumper JP1
        I/O address:
            switch 0 1 2 3 4 5
                   -----------
            200H - 0 1 1 1 1 1
            300H - 0 0 1 1 1 1
            310H - 0 0 1 1 1 0
            320H - 0 0 1 1 0 1
            330H - 0 0 1 1 0 0
            340H - 0 0 1 0 1 1