;Protocol.ini for the 3Com TokenLink
;Token-Ring cards
;
;PROTOCOL.INI PARAMETERS
;
; This is a sample PROTOCOL.INI file for the TLNK 3Com TokenLink NDIS MAC
; driver.  The [tlnk] section shows examples of TLNK configuration parameter
; settings.  Comments at the end of the file explain these parameters and give
; their default, minimum and maximum values.  The [protocol manager] and
; [netbeui] sections aren't meant to be complete or realistic examples, except
; for the "BINDINGS = tlnk" line in the [netbeui] section.
;	The only parameter that must be specified is the "drivername".  Note
; that many of these parameters have default values (which are given below
; under "Comments about tlnk parameters"). A parameter need not be specified
; in your PROTOCOL.INI if its default value is satisfactory.
;
;drivername
;     units:[n/a]
;     range:[tlnk$,tlnk2$,tlnk3$,...]
;     default:[tlnk$]
;
;     This parameter's value must be tlnk$, or, in the case where
;     multiple adapters are installed, tlnk$ for the first adapter's
;     drivername, tlnk2$ for the second one, tlnk3$ for the third, and
;     so on.
;
;The following entries are optional under the [tlnk] section.
;
;dmachannel (80286 and 80386 computers only)
;     units:[integer]
;     range:[0,1,3,5,6,7]
;     default:[1]
;
;     Sets the DMA channel on the network adapter card. This entry
;     is ignored when the adapter card is in an 8086 or 8088 computer, or
;     in an 8-bit slot of an 80286 or 80386 computer. Installing the card
;     in a 16-bit slot improves performance.
;
;     The value can be 0, 1, 3, 5, 6, or 7. When the value is 0, the driver
;     uses string I/O instead of DMA for data transfers. Channels 5, 6,
;     and 7 are available only if the adapter card is ASSY 3410-03 revision
;     A or later.
;
;interrupt
;     units:[integer]
;     range:[2-14]
;     default:[3]
;
;     Indicates the interrupt level of the network adapter card.
;
;     NOTE:
;     For an 80286 or 80386 computer, specifying interrupt level
;     2 will be redirected to interrupt level 9 because the cascaded PIC
;     is already using interrupt level 2.
;
;These are the possible interrupt values:
;
;Value                    Compatible Computers
;-----                    --------------------
;2,3,4,5                  8086 and 8088 computers.
;3,4,5,9                  80286 and 80386 computer, 8-bit slot.
;3,4,5,9,10,11,12,14,15   80286 and 80386 computer, 16-bit slot.
;
;(Levels 1014 are available only if the adapter card is ASSY 3410-03
;revision A or later.)
;
;ioaddress
;     units:[hex]
;     range:[300-350]
;     default:[300]
;
;     Indicates the current I/O address jumper configuration of
;     the network adapter card. This entry must match the adapter card's
;     switch settings. Possible values are 300, 310, 330, and 350.
;
;maxtransmits
;     units:[integer]
;     range:[8-40]
;     default:[8]
;
;     Specifies the number of transmit queue entries in this driver.
;     For a server, multiply the transmit window size by the maximum number
;     of sessions.
;
;netaddress
;     units:[hex]
;     range:[12 hex digits]
;     default:[n/a]
;
;     Overrides the network address of the network adapter card.
;     This entry should only be used if, for some reason, there are duplicate
;     addresses on the network. The value of this entry is a hexadecimal
;     string of 12 digits enclosed in quotation marks, such as "02608C010001".
;
;productid
;     units:[hex]
;     range:[36 hex digits]
;     default:[n/a]
;
;     Identifies the specific adapter card. The value of this entry
;     is a string of up to 36 hexadecimal digits (must be an even number).
;     Refer to the IBM Token-Ring architecture manual for more details.
;     The default value for this entry is 0110F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0.
;
;speed
;     units:[n/a]
;     range:[6-10]
;     default:[tlnk$]
;
;     Sets the computer's clock to maximize data transfer between
;     the computer and the TokenLink card. You may have to experiment with
;     this entry to get optimal performance. If you set the entry incorrectly,
;     the TokenLink card may not run. The value can be any of the following:
;
; Value    Meaning
; -----    -------
;  6       Insert two wait states on the bus.
;  8       Insert one wait state on the bus.
; 10       Don't insert any wait states on the bus.
;

