SETUP.TXT
MicroPhone Pro for Windows Version 1.0
October 30, 1992


IMPORTANT: WINFAX USERS
=======================

If you have used WinFAX before installing MicroPhone Pro, you must exit
and restart Windows before running MicroPhone Pro's SETUP program. 


SETUP INSTRUCTIONS
==================

To set up MicroPhone Pro, its documents and drivers, follow these steps. 
If you already own MicroPhone, back up your Settings Documents before 
running SETUP.  Full setup (including WinFAX Lite) requires about 4.25 MB 
of disk space.

1. Start Windows.

2. Insert the MicroPhone Pro Setup Disk into your floppy drive.

3. From the Windows Program Manager, choose Run from the File menu.

4. Enter the name of the floppy drive you are using followed by "SETUP"
   (e.g., A:SETUP), then choose OK.

5. When the Setup Program displays a dialog box asking for your name,
   serial number (located on the Ristration card in the Users Guide)
   and other information, enter them.  Then choose OK.

6. In the next dialog box, type the path and name for your MicroPhone Pro 
   directory (the default is C:\MPPRO\) and select a default comm port from
   the drop down ComboBox, then choose Continue.

7. Choose the "Set up all documents" option to set up all MicroPhone Pro
   documents, or choose "Set up selected documents" to select specific
   documents. Then choose the Continue button to start the setup procedure.

NOTE: If MicroPhone Pro was set up previously, the Setup Program will
      also ask what to do with existing MicroPhone Pro files.  You can 
      choose to rename existing files, overwrite them, or have the Setup 
      Program ask for confirmation before overwriting each file.  You can 
      also exit the program to back up your files and re-start the 
      installation.

      If you already own WinFax Pro or WinFax Lite, you do not need to 
      reinstall WinFax Lite included in this package. However, you may 
      still want to update your WinFax driver (WINFAX.DRV) in your Windows 
      System directory with the modified driver included in the MicroPhone 
      Fax subdirectory. The modified driver ensures smoother fax operation 
      with some Windows applications. If you install WinFax Lite with the 
      MicroPhone Setup Program, your current fax driver will be updated 
      automatically.


SETTING UP A SECOND TIME
========================

MicroPhone Pro's Setup Program provides the option to install only 
selected files.  To install files not installed the first time, or
install the original files again, follow the same instructions used 
for your initial setup.

When the Setup Program asks which documents to set up, choose "Setup 
Selected Documents."

In the resulting dialog box, select the documents you want to set up
and choose Continue.  The Setup Program will add the selected documents.

If you run Setup over existing documents, you may end up with duplicate 
icons in the Program Manager's MicroPhone Pro group.  If this happens, 
select each of the duplicate items and choose Delete from the File menu 
in the Program Manager.  If you run Setup using  a different directory, 
you will still get duplicate icons, but with the new path information. 
You should delete the old icons, checking the path, or change the icons 
so that you can distinguish between the old and new icons.

IMPORTANT: Do not run the Setup Program while MicroPhone Pro is running.
Problems can occur because the Setup Program may update a file in use by
MicroPhone Pro.


SETTING UP ON NETWORK
=====================

Software Ventures Corporation provides network license for installation
in a network environment; otherwise each user is required to purchase a 
seperate copy of MicroPhone Pro.  As long as one package is owned by each 
user, users can share the application and documents on a network file 
server.  Contact Software Ventures Corporation's sales department at 
(510) 644-3232 for information about network licensing.

MicroPhone Pro's Setup Program is designed to install to a local hard disk
or network servers that are designed to act like local hard disks.

Be sure that you have permission to write to the directory where
MicroPhone Pro is being installed.  If you specify a directory that
does not exist, the Setup Program will try to create the directory. 
Make sure you have permission to create the directory.  Follow the 
setup instructions above.


WHAT THE SETUP APPLICATION DOES
===============================

MicroPhone Pro's Setup Program will:

1. Create the application's directory if it does not already exist.

2. Decompress and copy MicroPhone-specific files to the application's 
   directory.

3. Make these changes in the Windows directory:
   - Add the *.mdc and *.wav associations to win.ini.
   - Copy MicPhone.ini, MPFax.ini and MPTran.ini into the Windows directory.

4. Copy these files to the Windows\System directory:
   micvt102.dll, mppcansi.fon, mpdecvt.fon and mlist.vbx.
   These files are also copied if needed:
   vbrun100.dll, shell.dll, commdlg.dll.

5. Update MicPhone.ini for installed documents and other information.

6. Build MicroPhone Pro's Program Manager group.

7. Open the ReadMe document upon confirmation.


NOTE: MicroPhone Pro's document names are not restricted like DOS 
      file names. These document names are listed in MicPhone.ini 
      under the Settings heading. If a document name is properly 
      listed in MicPhone.ini, you can use "MP2.exe" followed by the 
      document name in the command line of the Program Manager's 
      Properties dialog box. If it is not, you must use a full path 
      name.

      For network installation: MicroPhone Pro's profile file, 
      MicPhone.ini, must be located in the same directory as each 
      user's win.ini.  Each user must have write permission to this 
      file in order to use MicroPhone Pro. MPFax.ini and MPTran.ini 
      must be in this directory to use MicroPhone Pro's international 
      character translation tables.


SETTING UP UNDER NORTON DESKTOP
===============================

There have been reports of Windows problems when running MicroPhone Pro's 
Setup Program under the Norton Desktop utility version 1.0.  Here are
some suggestions of what to do if you do run into problems.

1. If possible, use Window's Program Manager to set up MicroPhone Pro.

2. If the Program Manager is not available, open Norton Desktop's 
   Preferences and turn off the Task List and Launch List, restart 
   Windows, and then run MicroPhone Pro's Setup Program.


FILE LIST
=========

This is a list of files which will be installed when the Category and Document
is selected during setup. The default MicroPhone Directory is C:\MPPRO\. The 
default Windows directory is C:\Windows\ and the windows system directory 
C:\Windows\System\.

Categories	Documents		Directory	File Names
----------	---------		---------	----------
MicroPhone	MicroPhone Pro		\MPPRO\		MP2.EXE
							MPFAX.EXE
							MPPRINT.EXE
							WATCH.EXE
							CHAT.DLL

		MicroPhone Sound Files	\MPPRO\		ERROR.WAV
							FULLBUFF.WAV
							XFERDONE.WAV
							XFERERR.WAV

		Dialing	Directory	\MPPRO\		DIALDIR.DLL
							DIALDIR.CRD

		Help File		\MPPRO\		MICPHONE.HLP

		Readme File		\MPPRO\		README.WRI
							SETUP.TXT

		Fax Profile		WINDOWS\	MPFAX.INI

		Translation		WINDOWS\	MPTRAN.INI
		Profile

		DEC VT Fonts		WINDOWS\SYSTEM\	MPDECVT.FON

		PC ANSI Fonts		WINDOWS\SYSTEM\	MPPCANSI.FON

		VT102 DLL		WINDOWS\SYSTEM\	MICVT102.DLL

Settings	MicroPhone Settings	\MPPRO\		MICPHONE.MDC
Documents
		BIX			\MPPRO\BIX\	BIX.MDC
							ADDRESS.TXT

		CompuServe		\MPPRO\CIS\	CIS.MDC
							ADDRESS.TXT

		Dow Jones		\MPPRO\DOWJONES\ DOWJONES.MDC

		FAX			\MPPRO\FAX\	FAX.MDC
							_REC_FAX.MDC
							SCRIPTS.TXT
							FAX.WRI

		GEnie			\MPPRO\GENIE\	GENIE.MDC
							ADDRESS.TXT

		Interface Template	\MPPRO\INTFACE\	INTFACE.MDC

		Launcher		\MPPRO\UTILITY\	LAUNCHER.MDC
							LAUNCHER.WRI

		MCI			\MPPRO\MCI\	MCI.MDC
							ADDRESS.TXT

		Mini BBS User		\MPPRO\BBSUSER\	MBBSUSER.MDC
							ADDRESS.TXT

		Mini BBS		\MPPRO\MINIBBS\	MINIBBS.MDC
							BULLETIN.TXT
							BULLET01.TXT
							USERS.TXT

		MultiMedia		\MPPRO\UTILITY\	MULTIMED.MDC
							MULTIMED.WRI

		SVC BBS			\MPPRO\SVCBBS\	SVCBBS.MDC
							ADDRESS.TXT
							PHONENO

		Script Bank		\MPPRO\UTILITY\	SCR_BANK.MDC
							SCR_BANK.WRI

		Utilities		\MPPRO\UTILITY\	UTILITIE.MDC
							UTILITIE.WRI

Modem Drivers	Farallon V.32		\MPPRO\MODEM\	FARA_V32.MDV
		GVC Tech 2400 MNP	\MPPRO\MODEM\	GVC24MNP.MDV
		GVC Tech 9600 V.32	\MPPRO\MODEM\	GVC96V32.MDV
		Hayes Smart 1200	\MPPRO\MODEM\	HAYES_12.MDV
		Hayes Smart 2400	\MPPRO\MODEM\	HAYES_24.MDV
		Hayes V-series		\MPPRO\MODEM\	HAYES_V.MDV
		Hayes Ultra		\MPPRO\MODEM\	HAYESULT.MDV
		Intel 2400 EX		\MPPRO\MODEM\	INTEL_24.MDV
		Intel 9600EX V.32	\MPPRO\MODEM\	INT96V32.MDV
		Multitech 2400E		\MPPRO\MODEM\	MULTI_24.MDV
		Multitech V.32		\MPPRO\MODEM\	MULTIMDM.MDV
		NEC N2431		\MPPRO\MODEM\	NEC_2431.MDV
		No MNP			\MPPRO\MODEM\	NOMNP.MDV
		Practical 2400SA	\MPPRO\MODEM\	PP_24SA.MDV
		Practical 9600/14.4	\MPPRO\MODEM\	PP_96SA.MDV
		Prometheus 2400		\MPPRO\MODEM\	PROM_24.MDV
		Prometheus Ultima	\MPPRO\MODEM\	PROM_ULT.MDV
		Prometheus V.32		\MPPRO\MODEM\	PROMODEM.MDV
		Standard Autobaud	\MPPRO\MODEM\	STND2400.MDV
		Standard FAX 2400	\MPPRO\MODEM\	STNDFAX.MDV
		Standard MNP		\MPPRO\MODEM\	STND_MNP.MDV
		Standard V.32		\MPPRO\MODEM\	STND_V32.MDV
		Supra 2400		\MPPRO\MODEM\	SUPRA_24.MDV
		Supra Fax Plus		\MPPRO\MODEM\	SUPRA_FP.MDV
		Supra V.32bis		\MPPRO\MODEM\	SUPRA_32.MDV
		Telebit T1000		\MPPRO\MODEM\	TB_T1000.MDV
		Telebit T1600		\MPPRO\MODEM\	TB_T1600.MDV
		Telebit T2000		\MPPRO\MODEM\	TB_T2000.MDV
		Telebit T2500		\MPPRO\MODEM\	TB_T2500.MDV
		TBit Trailblazer	\MPPRO\MODEM\	TB_TRAIL.MDV
		TBit T-blazer Plus	\MPPRO\MODEM\	TB_PLUS.MDV
		UDS FasTalk V.32	\MPPRO\MODEM\	UDS_V32.MDV
		USR Courier DualStd	\MPPRO\MODEM\	COURIER.MDV
		USR Courier HST		\MPPRO\MODEM\	USR_HST.MDV
		USR Courier V.32	\MPPRO\MODEM\	USR_V32.MDV
		Zoom 2400		\MPPRO\MODEM\	ZOOM_24.MDV
		Zoom V.32bis		\MPPRO\MODEM\	ZOOM_32.MDV
		Zoom V.42bis		\MPPRO\MODEM\	ZOOMV42.MDV
		
Connection	Default Connection	\MPPRO\CONNECT\	DEFAULT.CDV
Drivers		Com1			\MPPRO\CONNECT\	COM_1.CDV
		Com2			\MPPRO\CONNECT\	COM_2.CDV
		Com3			\MPPRO\CONNECT\	COM_3.CDV
		Com4			\MPPRO\CONNECT\	COM_4.CDV
		Com5			\MPPRO\CONNECT\	COM_5.CDV
		Com6			\MPPRO\CONNECT\	COM_6.CDV
		Com7			\MPPRO\CONNECT\	COM_7.CDV
		Com8			\MPPRO\CONNECT\	COM_8.CDV
		Com9			\MPPRO\CONNECT\	COM_9.CDV
		ComBIOS			\MPPRO\CONNECT\	COMBIOS.CDV
		NetBIOS			\MPPRO\CONNECT\	NETBIOS.CDV
		Novell NASI		\MPPRO\CONNECT\	NASI.CDV
		Ungermann Bass CI	\MPPRO\CONNECT\	UNG_BASS.CDV
		DOS Device Driver	\MPPRO\CONNECT\	DEVICE.CDV
		LAN+MODEM		\MPPRO\CONNECT\	LANMODEM.CDV
		None			\MPPRO\CONNECT\	NONE.CDV

Fax		WinFAX Lite Application	\MPPRO\FAX	WINFAX.DRV
					plus files from WinFax Lite installation
________________________________________________________________________________


List of files required to run MicroPhone Pro and automatically installed 
if they do not already exist.

Documents		Directory		File Names
---------		---------		----------
MicroPhone Setup,	\MPPRO\			SETUP.EXE
						SETUPD.EXE
						SETUP.INF

MicroPhone Profile,	WINDOWS\		MICPHONE.INI

Common Dialog DLL,	WINDOWS\SYSTEM\		COMMDLG.DLL (MS Windows 3.1)
Shell DLL,		WINDOWS\SYSTEM\		SHELL.DLL (MS Windows 3.1)
Dial Dir Control,	WINDOWS\SYSTEM\		MLIST.VBX (MS Visual Basic 1.0)
Visual Basic DLL,	WINDOWS\SYSTEM\		VBRUN100.DLL (MS VB 1.0)

________________________________________________________________________________




CONTACTING SOFTWARE VENTURES CORPORATION
========================================

If you have any comments or questions about MicroPhone Pro's 
Setup Program, you are welcome to use our bulletin board at 
(510) 849-1912 or call Technical Services at (510) 644-1325. 
Electronic mail addresses are available on the last page of 
the MicroPhone Pro manuals.

